www.omega.com e-mail: [email protected]’s GuideOME-DB-889D 16-Channel Analog Multiplexer BoardShop online at

Strany 2

2.3 Pin Assignment The OME-DB-889D provides two 37pin D-Sub connector & two 20-pin flat cable connector. The CN1, CN2 D-sub connector is analog

Strany 3

DOn : DO0~DO3 Multiplexer control bit. DO4~DO6 Gain control bit D. GND : Digital Ground +5V : PC’s +5V +12V PC’s +12V OME-DB-889D Us

Strany 4 - 1.3 Specification

3 Analog input & Gain setting 3.1 Input Channel Selection The DB-990D provides 15 channel differential analog inputs. Input channel selection

Strany 5

3.2 Gain Setting The high grade instrumentation provides software programmable gains or switch selectable gain of 0.5 1, 5, 10, 50, 100, 500, 1000.

Strany 6 - 2. Installing

3.3. The Thermocouple Input The OME-DB-889D can accept thermocouple sensor to measure temperature. The OME-DB-889D should be set to different gain va

Strany 7 - 2.2 Jumper setup

3.3.1 Voltage - TO - Temperature Conversion The temperature-versus-voltage relationship of a the thermocouple is not linear. You can reference the

Strany 8

3.3 CJC Output The OME-DB-889D provides Cold-Junction Compensation (CJC) for the thermocouple applications. If the CJC is required, place the JP17 in

Strany 9 - Local Gain Control

4 Signal Connection The OME-DB-889D can multiplex up to 16 channel differential inputs. Input channel selection is controlled by a CN3 D4~ D6 digit

Strany 10 - 2.3 Pin Assignment

4.2 Non-Floating Signal Source Some the signal source has one side connect to a local ground. The signal ground with OME-DB-889D ground will not be s

Strany 11 - OME-DB-889D User’s Manual

4.3 Cascading OME-DB-889D OME-A-82X series OME-DB-889D JP16 A/D Channel 0 OME-DB-889D #1 0 A/D Channel 1 OME-DB-889D #2 1 A/D Channel 2 OME-D

Strany 12

Servicing North America:USA: One Omega Drive, P.O. Box 4047ISO 9001 Certified Stamford CT 06907-0047TEL: (203) 359-1660 FAX: (203) 359-7700e-mail: inf

Strany 13 - 3.2 Gain Setting

4.4 Open Thermocouple Detection The OME-DB-889D provides open thermocouple detection through a resistor circuitry. These resisters are normally no

Strany 14 - 3.3. The Thermocouple Input

4.5 Block Diagram CN4 CN1CN3CN2 AMP16 channel Multiplexer Control Logic CJC Dip SwitchCN8 Connector with R/C filter VR1 VR2 CN6 C

Strany 15

5 Programming The OME-A-82x series multi-function card can support up to 160 channels by cascading 10 OME-DB-889D’s without complex programming. 5.1

Strany 16 - T(°C) = V*1000/24.4

5.3 Example Program DEMO_01.C /* ============== Using OME-A-822 / connect one OME-DB-889D =================*/ #include <stdio.h> #include “A8

Strany 17 - 4 Signal Connection

A822_DO(0x0021); /* Send D/O data to OME-DB-889D , Channel 1, Gain=10 */ delay(10); /* delay about 43u sec , Ref. Page 3 Setting tim

Strany 18 - Common mode signal input

OME-DB-889D User’s Manual 23 6. Calibration The OME-DB-889D is calibrated to its best of operation. For environment subjected to large vibrations,

Strany 19 - 4.3 Cascading OME-DB-889D

WARRANTY/DISCLAIMEROMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for aperiod of 13 months from date of

Strany 20

M4019/1103Where Do I Find Everything I Need for Process Measurement and Control? OMEGA…Of Course!Shop online at www.omega.comTEMPERATUREThermocouple

Strany 21 - 4.5 Block Diagram

OME-DB-889D MULTIPLEXER BOARD ...2 1. FUNCTION DESCRIPTION...

Strany 22 - 5.1 Using OME-A-822PGL

OME-DB-889D Multiplexer Board 1. Function Description The OME-DB-889D is an expansion multiplexer / amplifier board for use with OME-A-82X, OME-PCI-1

Strany 23 - 5.3 Example Program

Gain Common Mode Rejection Non linearity %of FSR Settling Time 0.5 99dB ±0.0004 23uS 1 99dB ±0.0004 23uS 5 114dB ±0.0004 28uS 10 99dB ±0.0004 28uS

Strany 24

2. Installing 2.1 Layout CJC Output External Voltage Input JP19 JP18VR2 VR1 Jumper /Connector Name Function Note CN1 Connect to A/D c

Strany 25 - 6.2 Calibration Steps

2.2 Jumper setup 2.2.1 JP0 ~ JP15 Analog Input R/C Filter The OME-DB-889D provides R/C filter with each analog input channel by jumper setting. Ch

Strany 26 - RETURN REQUESTS/INQUIRIES

2.2.3 JP19 Internal / External Power selection The OME-DB-889D requires single +5V power supply. the connector CN5 are used for the external power s

Strany 27 - Shop online at www.omega.com

Remote Gain Control When the JP18 is set to “R”, it means Remote Gain Control is selected and the gain is controlled by the digital signal of connec